Coupling Decoupling Network (CDN) for Conducted Immunity testing

red pointerFor Conducted Immunity Testing
red pointerMeets EN-61000-4-6 Requirements
red pointerPowerline Testing
red pointerSignal line Testing
red pointerThree Year Warranty

 

 

Coupling Decoupling Networks  - CDNs
 

Coupling Decoupling Networks (CDNs) for IEC / EN 61000-4-6 Testing

Com-Power CDNs are designed and constructed to comply with standard EN 61000-4-6 Immunity to Conducted Disturbances Induced by Radio Frequency Fields (also IEC-1000-4-6 and CISPR 16). Electronic products can be susceptible to interference from nearby transmitters due to signal coupling to external I/O cables of the product's This is especially true for products with long external power, communication and interface cables. The level of interference that product must be able withstand is defined in the standard. A CDN is used to couple the disturbing signals to the product I/O cables. These levels are are injected into the CDN using a suitable power amplifier (similar to Com-Power ACS-181 or ACS-230) and an RF signal generator.

The CDN consists of circuits for coupling and decoupling injected RF signals. The the coupling circuit injects the disturbing signal into the cables under test.. The decoupling circuit prevents the injected signal from reaching the auxiliary equipment (AE) connected to the EUT.

Each CDN is specific to the type of cable and corresponding connector. Com-Power offers an extensive range of CDNs to test most standard cable types. You may require additional CDNs to decouple or isolate all other cables that are not subjected to the test, but are connected to the EUT. EN 61000-4-6 standard requires that an appropriate CDN be connected in this situation.

Each CDN is calibrated to meet the performance requirement given in IEC-61000-4-6 standard prior to shipment. The impedance data and certificate of calibration is shipped with each unit.

Below is a brief description of each CDN type available from Com-Power:

M series CDNs for power line cables

Coupling Decoupling Networks are recommenced for all power supplies connections. The disturbing signals are to coupled to each conductor in the supply lines according to EN 61000-4-6 standard. The standard M series CDNs have a current rating of 25 Amps. Com-Power CDNs are available for power supplies from 1 to 5 conductors. These CDNs cover the frequency range of 150 kHz - 230 MHz.

C series CDNs for shielded coax cables

The C series CDNs are for coupling disturbing signals on to 50 Ohm (CDN-C50) and 75 Ohm (CDN-C75) shielded coax cables. These CDN have BNC connectors for EUT and AE connections.

AF series CDNs for unshielded signal cables

The AF series CDNs are for unshielded cables with two, four and eight conductors carrying low current. AF series CDNs are supplied with RCA connectors.

S Series CDNs for shielded signal cables

The S series CDNs are for shielded cables with single or multiple conductors. These CDNs are supplied with professional audio (RCA), D type and Centronics connectors.

T series CDNs for unshielded balanced pairs

The T series CDNs are for cables with unshielded balanced conductor pairs typically found in ISDN, DSL and Ethernet data transfer applications.

Calibration accessories for The CDN

The RF disturbance levels that EUT has to be subjected to (1 V/m, 3 V/m, 10 V/m RMS) is specified in EN-61000-4-6. The conducted immunity setup must be calibrated make sure the proper levels are being generated during the compliance test. This setup includes signal generator, power amplifier, directional coupler, CDN, attenuator, cables, etc. In order determine disturbance levels being generated the following additional accessories are needed. These adapters are made according to the requirements specified in EN-61000-4-6.

  • One set of shorting adapters for each type of CDN - Part# ADA-xxx ( xxx = model number)
  • Two 150 Ohm to 50 Ohm adapter - ADA-515
  • 50 Ohm terminator - Part # - TEP -050
 
Model cable type
CDN-M125E One wire cable - Single Phase or DC
CDN-M225E Two wire cable - Single Phase + Neutral
CDN-M325E Three wire cable - Single Phase + Neutral + Earth
CDN-M425 Four wire cable - Three Phase + Earth
CDN-M525 5 wire cable Three phase + Neutral + Earth
CDN-C50 50 Ohm Coax
CDN-C75 75 Ohm Coax
CDN-S1 single conductor shielded cable
CDN-S2 Two conductor shielded cable
CDN-S4 Four conductor shielded cable
CDN-S9 9 conductor shieled cable
CDN-S15 15 conductor shielded cable
CDN-S25 25 connductor shielded cable
CDN-AF2E 2 conductor ushielded cable
CDN-AF4E 4 conductor ushielded cable
CDN-AF8 8 conductor ushielded cable
CDN-T2E ushielded RJ11 cable - 1 line
CDN-T4E unshielded RJ11 cable - 2 lines
CDN-T8 unshielded RJ45 Ethernet cable

 