A 100 Watts Conducted Immunity System (High Power)
- Conducted Immunity System (CIS) to Test According to IEC 61000-4-6. CIS-100 is capable of generating power upto 100 watts.
- The CIS series test systems are configured to perform conducted immunity testing according to IEC 61000-4-6.
- The system includes ACS series power amplifier, Coupling Decoupling Network (CDN), directional couplers, attenuators, cables and CSAT software.
- These systems when properly configured are capable of testing your products to the all levels given in IEC 61000-4-6 up to 230 MHz.
- The IEC-61000-4-6 requires that an appropriate a coupling decoupling networks (CDN) with defined common mode impedance is used for testing conducted immunity. Com-Power has a wide variety of CDNs. The system can be customized include the CDNs to fit your application at the time of purchase.
- Before you begin testing with the CDN you will need to establish a calibrated drive levels corresponding to the test levels.
- When used with compatible signal generator and spectrum analyzer, the CSAT test software can fully automate this calibration and also perform the test. Com-Power CDNs are calibrated to meet the latest CISPR 16 test standards.